PVC WATERSTOPS POLYVINYLCHLORIDE WATERSTOPS |
SPECIFICATIONS:
U.S. Corps of Engineers Spec. CRD C 572
Bureau of Reclamation
Canadian General Standards Board 41-GP-35M,
Types I and III
Department of Agriculture-Soil Conservation
TVA Spec. PF 1026
Various State Highway and/or Public Works Depts.
CH2M-HILL
PVC WATERSTOPS
DESCRIPTION: BVS PVC Waterstops are extruded from high quality PVC resins that are plasticized and stabilized to offer long-life performance, resistance to abrasion and attack by ozone, oxygen, alkalies and waterborne chemicals. BVS PVC Waterstops are available in a variety of thicknesses, widths and center bulb sizes. The cross-section configuration features a multi-rib design for an effective grip and tenacious anchor to the concrete and a flexible, hollow center bulb to accommodate moderate extension and transverse movements.
USES: BVS PVC Waterstops are embedded in adjacent pours of concrete to prevent the passage of water from liquid-containing structures or through foundation walls and tunnels at construction and expansion joints.
ADVANTAGES AND BENEFITS:
APPLICATION: BVS PVC Waterstops should be securely held in place by splitting the concrete form. They are thermoplastic and may be field welded using an indirect heating element. When placing the concrete, thoroughly vibrate it around the waterstop to avoid honeycombs and to insure complete embedment of the ribbed flange.
| STANDARD SIZES: | NUMBER |
THICKNESS |
WIDTH |
![]() |
4316 |
3/16" (4.76mm) |
4" (101.6mm) |
6316 |
3/16" (4.76mm) |
6" (152.4mm) |
|
6380 |
3/8" (4.53mm) |
6" (152.4mm) |
|
9316 |
3/16" (4.76mm) |
9" (228.6mm) |
|
9380 |
3/8" (4.53mm) |
9" (228.6mm) |
Nos. 6380, 9316 and 9380 are furnished in rolls of 50 lineal feet (15.24 meters) each; Nos. 4316 and 6316 are 100 lineal feet (30.48 meters) each.
DUO-PVC WATERSTOPS


APPLICATION: The waterstop must be held securely in place by using split forms or any proper method for correct and firm positioning to assure total embedment of the waterstop flanges while concrete is placed. Place the "U" bulb exactly in the center of the joint with the fracture membrane in the direction of the hydrostatic head. Vibrate concrete around the waterstop to avoid honeycombs, voids and mix segregation, thus assuring complete bonding of concrete to waterstop ribs. On the second pour, copper-clad steel anchors may be used to secure the waterstop in proper position. Use 16-gauge tie wire to secure it to the form or reinforcing steel.
PACKAGING AVAILABLE IN TWO TYPES

Rolls of 50 lineal feet (15.24 meters) each
DESCRIPTION: BVS DUO-PVC Waterstops are produced as an extrusion from a high-grade polyvinylchloride (PVC) compound.
USES: BVS DUO-PVC Waterstops are embedded in concrete in either vertical or horizontal expansion joints, or control joints wherever differential or joint expansion is anticipated. Any situation where ground or hydrostatic water pressure is present, BVS DUO-PVC Waterstops will effectively prevent passage of liquid through, across or around joints in concrete structures. They keep water in structures such as reservoirs, dams, canals, swimming pools, tanks containers and aqueducts...keeps water out of basements, water and sewage plants, foundation walls, warehouses and the like. They also prevent joint leakage in bridges, stadiums, floor slabs, parking garages, wing walls and culverts.
ADVANTAGES AND BENEFITS:
PRECAUTIONS: Do not use direct flame or overheat waterstop during field splicing. Specifier and user shall determine suitability of product for specific applications and assume all responsibilities in connection therewith. Read and follow application information, precautions and Material Safety Data information.
NAIL-ON-DUO-PVC WATERSTOPS
Incorporating all the advantages of DUO-PVC Waterstops, this product adds the unique NAIL-ON principle...an important time and labor-saving feature because it eliminates the need for special split forms to hold the waterstop in position during concrete placement. The unit is easily attached to the concrete forms with a doubleheaded nail. Butt splicing DUO-PVC and NAIL-ON Waterstops is quickly accomplished on-the-job with a thermostatically controlled electric splicer. When electricity is not available, heat a steel plate on a plumbers torch and use it to melt the ends of the waterstop. When the solder melts and the ends become soft and molten, align and hold them firmly together until the bond is secure. Do not char the heated ends.

MATERIAL SPECIFICATIONS FOR ALL SEALTIGHT WATERSTOPS |
||
| Properties of Finished Waterstops | Test Method | Typical Value |
| Tensile Strength (finished waterstop) | ASTM D 638 | 2020 psi (13.94 MPa) |
| Ultimate Elongation (finished waterstop) | ASTM D 638 | 370 |
| Stiffness in Flexure | ASTM D 747 | 1620 psi (11.18 MPa) |
| Tear Resistance | ASTM D 624 | 372 lbs./in. (6.64 kg/mm) |
| Hardness, Shore A 10 | ASTM D 2240 | 84 |
| Low Temperature Brittleness @ -35ºF (-37ºC) | ASTM D 746 | Passed |
| Tensile strength after accelerated extraction | CRD C 572 | 2070 psi (14.28 MPa) |
| Elongation after accelerated extraction | CRD C 572 | 330% |
| Effect on Alkali after 7 days: | CRD C 572 | passed |
| Weight +0.06% | ||
| Hardness +1 | ||
| Color: Green | ||
| BVS Concrete Specialties Division of Special Concepts, LLC P.O. Box 171, Cresskill, NJ U.S.A 07626 Phone: (800) 370-7600 or (973) 733-9500, Fax: (973) 623-4939 Website: http://www.speconcepts.com |